The balcony that is only good before nine

A decision record somebody can price without pretending it is a construction drawing.

The modelled change, whether it has been tried at the place, the geometry it depends on, the annual consequence, what must be verified before ordering, what success looks like, and the questions the bid still has to answer.

October 30th, today's date

5:00 PM

Decision record · revision 1

A deciduous tree 16 ft 5 in south-west of the seat

Record demo-east-balcony-breakfast:1:deciduous-tree:2026:10:30:17. Read on 30th October 2026.

weak across seasons

A medium deciduous tree planted 16 feet 5 inches to the south-west, grown to about 26 feet, with a crown roughly 19 feet 8 inches across.

Baseline

Works

Morning coffee · The morning chair

Forecast

Works

No extra hours this day

Across the year

weak

The status does not move in any sampled season.

Survey standing: Mapped: Shade, sky view and daily light are computed from the geometry on this plan. Unmeasured dimensions remain estimates, not verified measurements.

Real-world trial: none yet. Everything above is a forecast from the plan.

Buy nothing yetTry a reversible version at the place and recheck it before this goes out to price.

Design intent dimensions

Height26 ft
Distance from reading point16 ft 5 in
Bearing245°

Four-season acceptance basis

SeasonBeforeAfterHoursControlling after
JanuaryNoNoHours not claimedWhat it feels like
AprilWorksWorksHours not claimednone
JulyNoNoHours not claimedWhat it feels like
OctoberWorksWorksHours not claimednone

The status does not move in any sampled season.

Site controls this price depends on

ControlValueProvenanceBefore ordering
The building69 ft highYou said so: You told us this, and it beats what the model worked out.recorded
Balcony parapet3 ft 5 in highMeasured: Taken with a tape, a compass or a clock at the place.recorded
The balcony above9 ft 10 in high; underside 8 ft 10 inMeasured: Taken with a tape, a compass or a clock at the place.recorded
The morning chairPoint at 3 ft 9 in above a floor 36 ft above datum; facing 90°You said so: You told us this, and it beats what the model worked out.recorded

Verification queue

  1. Who can actually see in. Sit where you actually sit and look around. Mark the one window or path you can see a person from. Until one exists, privacy is a question we are not answering rather than one that is fine.
    This is not a refinement. Nothing can answer this question until somebody marks it. · sit-there

Acceptance checks

  • Re-run the reading for morning coffee at The morning chair after installation and confirm the controlling failure is not worse than the forecast for this proposal.
  • Check the completed geometry against the decision record before accepting substitutions: height 26 ft, distance from reading point 16 ft 5 in, bearing 245°.
  • Confirm the installed intervention keeps the forecast annual behaviour (weak).
  • Photograph the completed work from the original reading point and record any change to view, glare, privacy line or usable hours that the model did not predict.

Questions every bid should answer

  1. How will you verify: Root room clear of the house and services?
  2. How will you verify: Mature spread that fits?
  3. Measure the actual height available before ordering: this is sized at 26 feet and about four inches either way changes whether it works.
  4. Mark 16 feet 5 inches out on the ground and stand there before committing. The geometry is only as good as that distance.
  5. Try the reversible version first, even badly. A week with a borrowed umbrella tells you more than a drawing.
  6. Still unanswered: privacy exposure.
  7. What exact product, fixing/anchoring method and maintenance regime is included in the price?
  8. Which dimensions or assumptions in this record would your proposal change, and why?
  9. What is excluded from the price: structural design, footing design, drainage, electrical work, planning/permit work, boundary verification or underground-service locating?

Explicit exclusions and professional boundaries

CheckMature size, root behaviour near foundations and drains, and local suitability are questions for a nursery or arborist who can see the site.
CheckModelled at maturity. Nothing about this helps for the first several summers.
CheckThis decision record is design intent and decision evidence, not a construction drawing, structural calculation, permit set, boundary survey or setting-out document.
CheckThis record does not determine wind or snow loading, foundation or footing geometry, attachment adequacy, drainage works, electrical compliance, buried-service clearance, property lines or required approvals. Those questions remain with qualified people who can inspect the site and selected product.

Reference basis